Technical Data
9-3
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Electrical Data
WARNING: The unit is designed for only one operating voltage. Operate
only at the operating voltage shown on the ID plate.
Available operating voltages 200 V
AC
3-phase without neutral (Delta)
230 V
AC
3-phase without neutral (Delta)
400 V
AC
3-phase with neutral (star WYE)
400 V
AC
3-phase without neutral (Delta)
480 V
AC
3-phase without neutral (Delta)
Permissible voltage
deviations
Power supply: " 10%
I/O: " 10%
Operating voltage
frequency
50/60 Hz
Melter fuse protection Refer to ID plate
Max. melter load Refer to ID plate
Key-to-line
Max. input
0 to 10 V
DC
0 to 20 mA
4 to 20 mA
0 to 100 kHz