Operation
4-36
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Melter
Entering/Exiting Standby
Refer to Control Panel − Overview − / V9 for information on standby setup.
Switching On/Off All Motors (Collective Enable)
Also refer to Initial Startup and Motor Startup Protection.
Fig. 4-27 V1
Only enabled motors can be switched on. Prerequisite: The system is ready
for operation.
Enabling
If there is no individual enable, the motors are enabled with the key Switch
all motors on/off (collective enable) AND via the interface Standard I/O with
the signal All motors ON (collective enable).
Switching on
If there are individual enables, the motors are switched on with the key
Switch all motors on/off (collective enable) AND via the interface Standard
I/O with the signal All motors ON (collective enable).
The indication lamp in the key can be different colors:
Gray (off): No collective enable on control panel
Yellow: Collective enable on control panel, but no motor running
Green: Motor running.
1
2
Pump1
Pump2
Fig. 4-28 Motor(s): Enable on the motor screen − switch on on the melter screen
NOTE: The Standard I/O interface signals All motors ON/OFF (collective
enable) and Enable motor can be disabled with a key. The motors can then
only be enabled and switched on via the control panel (Refer to Fig. 4-87
Motor enable).