Operation
4-30
P/N 7105144G
2008 Nordson Corporation
VersaBlue_NW
Temperature Parameters (contd.)
Fault
Overtemperature =
Setpoint temperature
+ Overtemperature fault delta*
Fault
Undertemperature =
Setpoint temperature
Undertemperature fault delta*
Overtemperature/undertemperature fault: 10 °C (18 °F)
NOTE: The values for Overtemperature/undertemperature fault are
differential values, not absolute temperatures.
Overtemperature
shutdown =
Setpoint temperature
+ (Overtemperature fault delta + 10 °C)*
Setpoint temperature
+ (Overtemperature fault delta + 20 °F)*
NOTE: The overtemperature shutdown is calculated and therefore can not
be changed.
Example
Setpoint temperature = 170 °C (338 °F),
Overtemperature fault = 60 °C (108 °F)
This results in
Fault Overtemperature at 230 °C (446 °F)
Overtemperature shutdown at 240 °C (466 °F).
During operation the operator increases the setpoint to 190 °C (374 °F);
the value Overtemperature fault delta is left unchanged. Mathematically, an
overtemperature fault indication would then occur at 250 °C (482 °F).
However, shutdown occurs at a fixed value of 245 °C (475 °F).

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nordson VersaBlue VB Series and is the answer not in the manual?

Nordson VersaBlue VB Series Specifications

General IconGeneral
BrandNordson
ModelVersaBlue VB Series
CategoryIndustrial Equipment
LanguageEnglish

Related product manuals