9 Use the relevant screw to adjust grinding
fineness to obtain the desired coffee quality.
5.3 CHANGING
THE CONDENSER
To access the condensers, the service engineer
will have to:
1 Switch off the machine.
2 Remove the left panel by taking out the two
screws with a Phillips head screwdriver from
the top and the two screws from the front.
To remove the condensers:
3 Disconnect the fastons.
4 Using a 13 millimetre wrench remove the
nut on the panel of the condenser and then
remove the condenser itself.