10.2 AUTO WASHING AND AIR
SOLENOIDS VALVES
To access open the right panel undoing the two
screws in top and the two screws in the front.
The autowashing and air valves are located in the
right part of the machine.
10.2.1 AUTOWASHING SOLENOID
VALVE
1 Disconnect the wires from the coil.
2 Remove the silicone pipe, the clip and the
discharge pipe of the third way.
3 With a phillips screwdriver, remove the two
screws holding the solenoid. Remove the
solenoid from the right side.
4 With a 12 wrench, loosen the teflon water
inlet pipe solenoid and remove it perma-
nently.