12.3.4 SETTING
1 From the service engineer mode menu,
press:
A The down
arrow key to select
the "setting" sub-menu.
B The ENTER
key to go into the
sub-menu.
The programs available are:
t Coffee temperature
t Steam temperature
t Group temperature
t Maintenance
t Grounds number
t Rinse group
t Washing block
t Washing warning
t Program ON-OFF
t Energy saving
t Day/hour
t Group setting 1
t Group setting 2
t Water filter L
t Decalcification
t Change password
COFFEE TEMPERATURE
It is possible to programme the temperature of
the water in the coffee boiler.
Pressing
ENTER it is possible to enter the
sub menu; the
keys are used to increase/
reduce the temperature of the water in the coffee
boiler tank (min. 80°C max. 105°C).
Press
ENTER
to confirm settings. Press
RESET
to quit the submenu.
STEAM TEMPERATURE
It is possible to programme the temperature of
the steam in the services boiler.
Pressing
ENTER
it is possible to enter the
sub menu; the
keys are used to increase/
reduce the temperature of the steam in the ser-
vices boiler tank (min 80°C max. 150°C).
Press
ENTER
to confirm settings. Press
RESET
to quit the submenu.
Edition 02 to 02/2014
12.10
SERVICE MANUAL
Fig. 285
03:26
Fig. 286
03:29
Fig. 287
03:52