206
LP-1030/LP-1030-MF User's Manual for Basic Printer Operation
T
Error Log Reference
(1) (2) (3) Message Meaning Action
W PD A600 RASTER_DECODE_ERR
An error exists in the format of the compression
raster data.
Check on the computer side
for an error in the format of the
compression raster data.
W PD A601 RASTER_FORMAT_ERR
No raster data of the size specied in the data. Check on the computer side for an
error in the data.
W PD A700 PDL ERR 700
A controller internal format error occurred. When the error persists and there is
a problem in the printout, upgrade
the system.
W PD A701 PDL ERR 701
W PD A702 PDL ERR 702
W PD A703 PDL ERR 703
W PD A704 PDL ERR 704
W PD A705 PDL ERR 705
W PD A800 FORMATERROR
An error exists in the TIFF data. Alternatively,
cannot print because a required tag is missing.
Correct the error on the computer
side.
W PD A801 # OF PARAM. ERROR
The number of parameters for the TIFF data tags
is incorrect.
W PD A802 PARAM._RANGE_ERR
The parameter value for the TIFF data tags is
outside the supported range.
W PD A803 DATA IGNORED
Data was disregarded because there was no
valid print data in the TIFF data.
Check on the computer side whether
valid print data is being transmitted.
W PD A900 FORMATERROR
Cannot print because the required CALS format
record is missing.
Correct the error on the computer
side.
W PM 2300
HDD format execution Restart the Printer, and when the
error persists, upgrade the system.
W PM 7E01
Factory default setting execution
W PM 7E02
Printer initialization execution
W PM B800
Login unauthenticated
W PM C100
Internal communication parameter error
W PM C200
Statuses do not match
W PM C300
Internal process parameter error
W PN 2600
Panel unit not connected
Occurs when a response cannot be received for
the panel initialization command.
(Occurs in a panel task)
W PN 2610
Undened command received
Occurs when an undened command is received
from the panel unit.
(Occurs in a panel task)
Restart the Printer.
W PN 2620 Cmd Retry
Command resent because there was no
response for the command from the panel for a
certain time.
(Occurs in a panel driver)
W PN 2630 Cmd Timeout
Disposed of the command because the
command from the panel was interrupted
partway.
(Occurs in a panel driver)
W PN 2640 Pipe Overow
Disposed of the command from the panel
because of an upper pipe overow.
(Occurs in a panel driver)
-
W RM 2B01 Resource open error
Resource le opening error Restart the Printer.
W SC 2300 Image Over Run
Image disk writing too late Restart the Printer, and when the
error persists, upgrade the system.
W SN 6000
Setup access error -
W SN C000
MIB information construction error -
W SN C010
MIB information access error -
W SN C020
Internal communication error -
W SP A000 Cannot Parse PJL
PJL analysis failed
* Details may be divided into multiple items
Check the print data.