419
Auxiliary Area Section 9-11
Pulse Output 0 No-
origin Flag
A28005 ON when the origin has not been determined for
pulse output 0 and goes OFF when the origin
has been determined.
0: Origin established.
1: Origin not established.
Read only Turned ON when
power is turned
ON.
Turned ON when
operation starts.
Refreshed when
pulse output
starts or stops.
Refreshed each
cycle during the
overseeing pro-
cesses.
Pulse Output 0 At-
origin Flag
A28006 ON when the pulse output PV matches the ori-
gin (0).
0: Not stopped at origin.
1: Stopped at origin.
Read only Cleared when
power is turned
ON.
Refreshed each
cycle during the
overseeing pro-
cesses.
Pulse Output 0 Out-
put Stopped Error
Flag
A28007 ON when an error occurred while outputting
pulses in the pulse output 0 origin search func-
tion.
The Pulse Output 0 Output Stop Error code will
be written to A444.
0: No error
1: Stop error occurred.
Read only Cleared when
power is turned
ON.
Refreshed when
origin search
starts.
Refreshed when a
pulse output stop
error occurs.
Pulse Output 1
Accel/Decel Flag
A28100 This flag will be ON when pulses are being out-
put from pulse output 1 according to an
ACC(888) or PLS2(887) instruction and the out-
put frequency is being changed in steps (accel-
erating or decelerating).
0: Constant speed
1: Accelerating or decelerating
Read only Cleared when
power is turned
ON.
Cleared when
operation starts or
stops.
Refreshed each
cycle during over-
see process.
Pulse Output 1
Overflow/Underflow
Flag
A28101 This flag indicates when an overflow or under-
flow has occurred in the pulse output 1 PV.
0: Normal
1: Overflow or underflow
Read only Cleared when
power is turned
ON.
Cleared when
operation starts.
Cleared when the
PV is changed by
the INI(880)
instruction.
Refreshed when
an overflow or
underflow occurs.
Pulse Output 1 Out-
put Amount Set Flag
A28102 ON when the number of output pulses for pulse
output 1 has been set with the PULS(886)
instruction.
0: No setting
1: Setting made
Read only Cleared when
power is turned
ON.
Cleared when
operation starts or
stops.
Refreshed when
the PULS(886)
instruction is exe-
cuted.
Refreshed when
pulse output
stops.
Name Address Description Read/Write Times when data is
accessed