421
Auxiliary Area Section 9-11
Pulse Output 0 Stop
Error Code
A444 When a pulse output stop error occurred with
pulse output 0, the corresponding error code is
written to this word.
Read only Cleared when
power is turned
ON.
Refreshed when
origin search
starts.
Refreshed when a
pulse output stop
error occurs.
Pulse Output 1 Stop
Error Code
A445 When a pulse output stop error occurred with
pulse output 1, the corresponding error code is
written to this word.
Read only
Pulse Output 0
Reset Bit
A54000 The pulse output 0 PV (contained in A276 and
A277) will be cleared when this bit is turned from
OFF to ON.
Read/Write Cleared when
power is turned
ON.
Pulse Output 0 CW
Limit Input Signal
Flag
A54008 This is the CW limit input signal for pulse output
0, which is used in the origin search. To use this
signal, write the input from the actual sensor as
an input condition in the ladder program and out-
put the result to this flag.
Read/Write Cleared when power
is turned ON.
Pulse Output 0 CCW
Limit Input Signal
Flag
A54009 This is the CCW limit input signal for pulse out-
put 0, which is used in the origin search. To use
this signal, write the input from the actual sensor
as an input condition in the ladder program and
output the result to this flag.
Read/Write
Pulse Output 1
Reset Bit
A54100 The pulse output 1 PV (contained in A278 and
A279) will be cleared when this bit is turned from
OFF to ON.
Read/Write
Pulse Output 1 CW
Limit Input Signal
Flag
A54108 This is the CW limit input signal for pulse output
1, which is used in the origin search. To use this
signal, write the input from the actual sensor as
an input condition in the ladder program and out-
put the result to this flag.
Read/Write
Pulse Output 1 CCW
Limit Input Signal
Flag
A54109 This is the CCW limit input signal for pulse out-
put 1, which is used in the origin search. To use
this signal, write the input from the actual sensor
as an input condition in the ladder program and
output the result to this flag.
Read/Write