96
Offline Simulation Section 6-4
Executing the Timing Chart
1,2,3... 1. Input ON/OFF patterns for the input tags that you add to the timing chart.
2. Click the Execute Timing Chart Icon . Click the Icon to execute one
pulse (i.e., step) at a time.
Note (1) Executing simulation using the Program Window and executing simula-
tion using the timing chart cannot be performed at the same time.
(2) The time for one pulse can be set using the timing chart options.
ON/OFF patterns for any input tags can
be input in advance.
Input "S" from the keyboard to set to ON.
Input "R" from the keyboard to reset to OFF.
Used to execute
and stop the
timing chart.
Output tag values are displayed
when the timing chart is executed.
Press the space bar on the keyboard to
reverse the status.
Timing chart
options