Overview Section 5-1
Precautions for Correct Use
The G9SP Configurator cannot be used if it is connected to an RS-232C
Option Board or Ethernet Option Board. Always connect it directly to the
USB port.
Do not turn OFF the power supply to the G9SP-series Controller or discon-
nect the USB cable while online. Before removing the USB cable, place the
application offline.
The computer cannot be placed on standby while it is connected to the
G9SP-seried Controller with a USB cable.
5-1-2 G9SP Configurator Functions
The G9SP Configurator can be used for the following purposes.
Setup and Programming
G9SP Configurator
Debugging and Maintenance
Safety Output
Terminal Settings
Unit Configuration
Logic Editor
User-defined Function Blocks
Hardware Settings
System Settings
Programming
Offline Simulation
Online Monitoring
Other Functions
Displaying and
Printing Reports
Access Rights
Force-set/reset
The program can be debugged on the computer.
The actual I/O of the G9SP-series Controller can be turned ON and OFF.
Search Functionality
You can search for I/O tags and error locations in the program.
Settings can be checked and printed.
Safety-certified function blocks
are used to program the
G9SP-series Controller.
The hardware configuration and Safety I/O terminals of the G9SP-series
Controller are set here.
The cycle time and other software functions of the G9SP-series
Controller are set here.
The program execution status, error log, and other items in the G9SP-series
Controller can be monitored.
Protections can be set using passwords for changes to settings in the G9SP-series
Controller and to accessing and editing project files on the computer.