81
Creating Configuration Data Section 6-2
6-2 Creating Configuration Data
First, start the G9SP Configurator, and then make the hardware settings, per-
form programming, and make the system settings, in that order.
6-2-1 Starting the G9SP Configurator
1,2,3... 1. Select Programs/All Programs - OMRON G9SP Configurator - G9SP
Configurator from the Windows Start Menu.
2. Select Create New Project or Open Existing File from the Startup Oper-
ation Selection Guide.
Precautions for Correct Use
You must have administrator rights to manipulate user-defined function
blocks.
Refer to 6-5-4 Starting the G9SP Configurator When Manipulating User-
defined Function Blocks.
This section describes how to create a new project using an example from
Appendix A Emergency Stop Pushbutton Application.
6-2-2 Hardware Settings
First, make the hardware settings for the G9SP-series Controller.
1,2,3... 1. Unit Configuration
Drag and drop the model of the G9SP-series Controller and the Expansion
I/O Units to connect. It is not necessary to select the option board to con-
nect.
2. Selecting I/O Devices to Connect
Select the external devices to connect to the Safety I/O terminals. Also,
edit the I/O comments and test sources. For details on Safety I/O function-
ality, refer to 2-1-5 Safety Inputs and 2-1-6 Safety Outputs.
Settings can be performed while
confirming the current setup phase.
You can drag and drop the G9SP-series
Controller and the Expansion I/O Units.
You can jump to any setup display
by clicking one of the buttons.
Overall configuration information is displayed.

Table of Contents

Related product manuals