156
Debugging in Force Mode Section 10-3
Ending Force Mode
There are three ways to end Force Mode.
Ending Force Mode with the G9SP Configurator
Program execution is stopped and the G9SP-series Controller enters the
normal IDLE Mode when Force Mode is ended or Force Mode times out.
The I/O that were force-set or force-reset are returned to the actual values
when Force Mode ends.
Elapse of Force Mode Duration Time
Program execution is stopped and the G9SP-series Controller enters the
IDLE Mode when the Force Mode Duration Time expires.
The I/O that were force-set or force-reset are returned to the actual values
when Force Mode ends.
Changing Controller to a Mode Other Than IDLE or RUN
The mode will be changed by downloading, resetting, turning OFF the power
supply. The Force Mode will continue, however, if a change is made between
IDLE Mode and RUN Mode.
Force Mode at Startup
If the power supply is turned OFF while the G9SP-series Controller is in Force
Mode, the G9SP-series Controller will start the next time in a normal mode.
Start the Force Mode again if required.
Procedure and Windows
1,2,3... 1. Starting Force Mode
Press the (Start/Restart Force Mode) Button in the Program Monitor-
ing Window. Enter the Device Password and duration time in the following
dialog box. The background in the Program Window will change to orange
and “Force Mode” will be displayed at the lower right of the window.
Input tag N actual data
Input tag N force-
set/reset data
Start of
Force
Mode
Force-
set
Force-
reset
Force-
set
End of
Force
Mode
Enter the Force Mode Duration
Time. The upper limit is 1,440
minutes (24 hours).
Enter the Device
Password.