166
Restoring Data to G9SP-series Controller Section 11-3
If an error occurs during the restore operation, the ERR/ALM indicator will
light red, and a terminal number will light red to indicate the error details on
the Safety Input terminal indicators. Refer to 13-2 Error Details and Measures
to remove the error.
Precautions for Correct Use
• Operation will always start in restore waiting status when startup is per-
formed with the Memory Cassette inserted into the G9SP-series Controller
using the default settings. Make sure the Memory Cassette is not inserted
when downloading the configuration data from a computer.
• Verification of the configuration ID is performed to prevent restoring incor-
rect configuration data.
!WARNING Serious injury may possibly occur due to loss of required safety functions.
Once the data has been restored from the Memory Cassette, check that the
configuration data of the G9SP-series Controller is correct in that it operates
properly and carry out the validation testing (User Testing).
Not lit
Lit yellow
MS
MC
IN LED 0 1 2 3 4 5 6 7 8 9
The corresponding I/O indicators will
light to show the type of error.
Lit red
ERR/ALM
Restore error
MEMORY