188
Application Templates Appendix A
Timing Chart
Safety I/O Terminal Settings
Program
Precautions for Safe Use
Perform a function test every six months to detect contact welding failures on contactors.
It is the user's responsibility to make sure that the entire system complies with standards.
For safety reasons, two electrical switching elements and two mechanical actuators are
always necessary to detect electrical faults and mechanical faults.
Hazard
approaches.
S2 detects a
human body.
Reset ON
E-Stop S1
SLC1
S2
SLC2
S3
Reset S4
EDM feedback
KM1, KM2
Idle Run
More than
350 ms
More than
350 ms
S2 detects a human body and S3
detects the robot arm.
E-Stop released
E-Stop pressed
S3 detects the
robot arm.
Hazard (e.g., robot arm) is
interrupting light to S3 and stopped.
More than
350 ms