195
Application Templates Appendix A
D40Z Non-Contact Switch Application
Application Overview
Motor M stops when emergency stop pushbutton S1 is pressed.
Motor M is stopped by opening the connection with the safety door (D40Z No-contact Switch) at S2.
Wiring Example
Note Refer to SECTION 2 Part Names and Specifications for the terminal arrangement.
Timing Chart
Safety category/PL Safety device Stop category Reset
Equivalent to 4/PLe. Emergency stop pushbutton
D40Z Non-contact Switch
0 Manual
E1, E2, and E3: 24-VDC power supplies
S1: Emergency stop pushbutton
S2: D40Z Non-contact Switch
S3: Reset switch
KM1and KM2: Contactors
M: Motor
More than 350 ms
More than 350 ms
More than 350 ms
Idle Run
Reset ON
E-Stop pressed
E-Stop released
Gate close
Open
E-Stop S1
Non-contact Switch S2
Reset switch S3
KM1 and KM2
EDM feedback