5-52
5-16 User Parameters
5
Operating Functions
Pn01 Defa ult Display
Explanation of Settings
• Select the data to be displayed on the 7-segment display on the front panel after the power supply
is turned ON.
• For information on the display, refer to 6-4 Setting the Mode on page 6-7.
Pn01
Default Display
Setting range 0 to 17 Unit --- Default setting 1
Power OFF→ON
Yes
Setting Explanation
0 Position deviation
1 Servomotor rotation speed
2 Torque output
3 Control mode
4 I/O signal status
5 Alarm code and history
6 Software version
7 Warning display
8 Regeneration load ratio
9 Overload load ratio
10 Inertia ratio
11 Total feedback pulses
12 Total command pulses
13 Reserved
14 Reserved
15 Automatic Servomotor recognition display
16 Analog input value
17 Reason for no rotation