Setting Measurement Items
ZFX-C User’s Manual
3
SETTING THE MEASUREMENT CONDITIONS
53
Threshold
This function sets the judgment conditions.
X MENU mode - [Setup] - [Item] - [Limits]
Image adjustment (if necessary)
The following items can be changed and set to the image of the measurement target.
X MENU mode - [Setup] - [Item] - [Img Adj]
Setup Item Description
Correlation Sets the range of the correlation to be judged as OK.
Range: 0 to 100
Position XY Sets the range of movement in the X- and Y-axes of the measurement target to be judged
as OK.
Range: -9999.999 to 9999.999
(When calibration is OFF, the range of movement for positions X and Y are 0 to 640 and 0
to 480, respectively.)
Angle Sets the range of rotation angle to be judged as OK.
Range: -180 to 180
+/- direction of angle p.47
Item Description
Select camera
For details, see "Image Adjustment". p.99
Color filter
Filtering
BGS level