HEX sensor overload. This could be due to overload or
Auto-calibration is needed. See User Manual for full
details. Auto-calibration or HEX sensor restart is
required to close this message. If message persists
after Auto-calibration, please see User Manual under
Auto-calibration for details.
•
Error code: 4096
or this message, if no Auto-Calibration has been performed yet:
•
HEX sensor overload. Eliminate cause of overload, if
already done, use Auto-Calibration function. Please see
User Manual under Auto-calibration for details.
•
Error code: 128
To eliminate the Faulty sensor status, initiate an auto-calibration.
Auto-calibration
Auto-calibration is an option to prolong the time the sensor is in service before it is sent back
for OnRobot factory re-calibration. Auto-calibration can be done onsite, and it takes only a
couple of minutes.
NOTE:
Auto-calibration tab does not appear if the firmware version of the HEX sensor
is lower than 2.15. If your firmware version is higher than 2.09 please go to the
6.1.7. Web Client: Update Menu and update your firmware. For firmware
versions lower than 2.09 please contact your distributor.
Required steps to do an auto-calibration:
1. Stop the robot.
ADDITIONAL SOFTWARE OPTIONS
152