P Series User Guide 210
0x2007
Main Power Fail Check Time ALL
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
UINT 0 to 5000 20 ms RW No
Yes
Set the main power fail check time. Checks the main power fail by detecting instant
voltage drop, which may occur due to external power supply statuses. Please set the
value appropriate for the condition of the external power supply.
0x2008
7SEG Display Selection ALL
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
UINT 0 to 100 0 - RW Yes
Yes
Sets the items to display at the 7SEG window
Display Item Unit Description
1 Speed feedback
2 Speed command
5
Accumulated operation
overload rate
0.1%
7
Accumulated regeneration
overload rate
0.1%
11 Drive temperature 1 °C
Temperature around the drive’s power
device
Internal temperature of the drive
Internal temperature of the encoder
0x2009
Regeneration brake Resistor Configuration ALL
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
UINT 0 to 1 0 - RW No Servo Off Yes
Settings related to regeneration brake.