Parker Hannifin
P Series User Guide 242
Setting for Multi-Step Operation Speed 3 in Velocity operation mode. It is the speed
when input contact SPD2 is ON while SPD1 and SPD3 are OFF.
Multi-Step Operation Speed 4
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDOAll
ocation
Change
Property
Stor
e
INT -32768 to 32767 100 rpm RW No
times
Yes
Setting for Multi-Step Operation Speed 4 in Velocity operation mode. It is the speed
when input contact SPD1 and SPD2 are ON while SPD3 are OFF.
Multi-Step Operation Speed 5
e
Setting Range
Default
Value
Unit
Acces
sibility
PDOAll
ocation
Change
Property
Stor
e
INT -32768 to 32767 200 rpm RW No
Yes
Setting for Multi-Step Operation Speed 5 in Velocity operation mode. It is the speed
when input contact SPD3 is ON while SPD1 and SPD2 are OFF
Multi-Step Operation Speed 6
e
Setting Range
Default
Value
Unit
Acces
sibility
PDOAll
ocation
Change
Property
Stor
e
INT -32768 to 32767 500 rpm RW No
times
Yes
Setting for Multi-Step Operation Speed 6 in Velocity operation mode. It is the speed
when input contact SPD1 and SPD3 are ON while SPD3 is OFF.
Multi-Step Operation Speed 7
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDOAll
ocation
Change
Property
Stor
e
INT -32768 to 32767 1000 rpm RW No
times
Yes
Setting for Multi-Step Operation Speed 7 in Velocity operation mode. It is the speed
when input contact SPD2 and SPD3 are ON while SPD1 is OFF.
Multi-Step Operation Speed 8
e
Setting Range
Default
Value
Unit
Acces
sibility
PDOAll
ocation
Change
Property
Stor
e
INT -32768 to 32767 1500 rpm RW No
Yes
Setting for Multi-Step Operation Speed 8 in Velocity operation mode. It is the speed
when input contact SPD1, SPD2 and SPD3 are OFF.