Show the multi-turn data of multi-turn encoder.
0x260B
Drive Temperature 1 ALL
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
INT - -
℃
RO No - No
The temperature is measured with the built in temperature sensor in the drive’s
power board. When the measured value is 95 or above, the drive overheating alarm
1(AL-22) is set off.
0x260C
Drive Temperature 2 ALL
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
The temperature is measured with the built in temperature sensor in the drive’s
power board. When the measured value is 90 or above, the drive overheating alarm
1(AL-25) is set off.
0x260D
Encoder Temperature ALL
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
Shows the temperature measured by the built in sensor of serial encoders (when encoder format
(0x0201) is 4). When the measured 90 or above, the encoder heat (AL-26)sets off.
0x260E
Motor Rated Speed ALL
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
Show the rated speed of the drive motor.
0x260F
Motor Maximum Speed ALL
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
Show the drive’s maximum speed.
0x2610
Drive Rated Current ALL