Page #269 background image
Parker Hannifin
P Series User Guide 267
0x605B
Shutdown Option Code ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT 0 to 1 0 - RW No
At all
times
Yes
Sets the actions for servo drive shut down. (Operation Enable state ->Ready to Switch
On state)
Set Value Descriptions
0 Do not use
1
Deceleration and stop, Switch On Disabled and stop, Ready
status
0x605C
Disable Operation Option Code ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT 0 to 1 1 - RW No
At all
times
Yes
Set the option code for disable operation status. (Operation Enable state  Switched
On state).
Set Value
Descriptions
0
Do not use drive function
1
Deceleration and stop, movement with the Switch On
Disable, not ready..
0x605D
Halt Option Code ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT 0 to 4 0 - RW No
At all
times
Yes
Halt option code sets the movement method when moving from operation enable state
to switched on state.
Set Value
Descriptions
1
Deceleration and stop, Operation Enabled
2
Deceleration and stop with quick stop deceleration, Operation
Enabled
3
Deceleration and stop with torque limit torque, Operation
Enabled
www.comoso.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker P Series and is the answer not in the manual?

Parker P Series Specifications

General IconGeneral
BrandParker
ModelP Series
CategoryServo Drives
LanguageEnglish

Related product manuals