P Series User Guide 268
0x605E
Fault Reaction Option Code ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
INT 0 0 - RW No
At all
times
Yes
Set the action method for fault action to protect the drive’s system.
Set Value
Descriptions
0 Do not use servo drive functions. Keep the motor at free run.
0x6060
Modes of Operation ALL
Variable
Format
Setting
Range
Default
Value
Unit Accessibility
PDO
Allocation
Change
Property
Store
SINT 0 to 10 0 - RW Yes
At all
times
No
Set the operation mode for the servo drive. After turning the power on, the driver the
master determines the operation mode.
The drive provides the following operation modes.
Set Value
Name
Description
-1
IP
Indexing Position / Pulse Input Position
0
-
No mode allocation
1
-
Reserved
2
-
Reserved
3
-
Reserved
4
-
Reserved
6
HM
Homing mode
7
-
Reserved
8
-
Reserved
9
-
Reserved
10
-
Reserved
Other
-
Reserved
0x6061
Modes of Operation Display ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
SINT
-
-
-
RO
Yes
-
No
Set the operation mode of the drive.
0x6062
Position Demand Value ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
DINT
-
-
UU
RO
Yes
-
No
www.comoso.com

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Parker P Series and is the answer not in the manual?

Parker P Series Specifications

General IconGeneral
BrandParker
ModelP Series
CategoryServo Drives
LanguageEnglish

Related product manuals