Parker Hannifin
P Series User Guide 273
Setting Range
Unit
Store
Setting Range
Unit
Store
UDINT 0 to 0x40000000 1 - RW No
Yes
Setting Range
Unit
Store
UDINT 0 to 0x40000000 1 - RW No
Yes
See “ 6.5 Electronic Gear Setting “ for further details
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
SINT -128 to 127 34 - RW No
Yes
Set homing method. See “ 6.4 Homing “ for further details.
0 Do not use homing
Homing using index pulse and negative limit contact
2 Homing using index pulse and positive limit contact
7 to 14 Homing using index pulse and home limit contact
24 Same as 8 (does not use index pulse)
28 Same as 12 (does not use index pulse)
33, 34 Homing with index pulse
Homing with current position
-1 Homing using negative stopper and index pulse
-2 Homing using positive stopper and index pulse
-3 Homing using only negative stopper
-4 Homing using only positive stopper
0x6099
Homing Speeds
Setting Range
Unit
Store
Speed during search for switch
Setting Range
Unit
Store
Speed during search for zero