EasyManua.ls Logo

Parker P Series - Page 275

Parker P Series
316 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Parker Hannifin
P Series User Guide 273
SubIndex 0
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
USINT
-
2
-
RO
No
-
No
SubIndex 1
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
UDINT 0 to 0x40000000 1 - RW No
Power
Resupply
Yes
SubIndex 2
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
UDINT 0 to 0x40000000 1 - RW No
Power
Resupply
Yes
See ā€œ 6.5 Electronic Gear Setting ā€œ for further details
0x6098
Homing Method
ALL
Variabl
e
Format
Setting Range
Default
Value
Unit
Acces
sibility
PDO
Allocati
on
Change
Property
Stor
e
SINT -128 to 127 34 - RW No
At all
times
Yes
Set homing method. See ā€œ 6.4 Homing ā€œ for further details.
Set Value
Descriptions
0 Do not use homing
1
Homing using index pulse and negative limit contact
2 Homing using index pulse and positive limit contact
7 to 14 Homing using index pulse and home limit contact
24 Same as 8 (does not use index pulse)
28 Same as 12 (does not use index pulse)
33, 34 Homing with index pulse
35
Homing with current position
-1 Homing using negative stopper and index pulse
-2 Homing using positive stopper and index pulse
-3 Homing using only negative stopper
-4 Homing using only positive stopper
0x6099
Homing Speeds
SubIndex 0
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
USINT
-
2
-
RO
No
-
No
SubIndex 1
Variable
Format
Setting Range
Default
Value
Unit
Accessib
ility
PDO
Allocation
Change
Property
Store
DINT
0 to 0x40000000
500000
UU/s
RW
No
At all times
Yes
SubIndex 2