Parker Hannifin
P Series User Guide 274
Setting Range
Unit
Store
Set the operation speed for homing.
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
UDINT 0 to 0x40000000 200000 UU/s
2
RW No
Yes
Set operation acceleration for homing.
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
DINT
-2147483648 to
2147483647
0 UU/s RW Yes
No
Correspond to speed feed forward value for position control.
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
INT -5000 to 5000 0 0.1% RW Yes
No
Correspond to torque feed forward value for position control.
e
Setting Range
Default
Value
Unit
Acces
sibility
Allocati
Change
Property
Stor
e
UINT 0 to 0xFFFF 0x0033 - RW Yes
Yes
Sets touch probe functions.
bit value Descriptions
0
1
Trigger by touch probe 1 input