52
Select 1. SP and press [ENT] to view SP screen.
Input PN ( Point Name ), X, Y, Z, and PC ( Point Code ) of SP point or import from the memory of
rectangular coordinate as SP by [F2][LIST].
If you finish the input of SP value, press [F5][ACCEPT]. Then you go to EP input screen.
Input EP value like an input of SP. If you finish an input of P2, press [F5][ACCEPT]. Then you go to
CP input screen.
If you finish the input of CP value, press [F5][ACCEPT]. Then you go to RADIUS input screen.
If you finish the input of RADIUS, press [ENT]. Then you go to RESULT OF LINE-ARC INTERSECTION
screen.
You can see the coordinates of one of intersection point. You can switch to one more intersection
point by pressing [F3][ONE MORE].
Press [F5][ENT] to save an intersection point.
The PN, X, Y, Z and PC are viewed and can be edited.
If all items are OK, press [F5][ACCEPT] to save them.