75
11. Traverse
This function is for fixed, closed and open traverse calculations.
You can measure not only the corner points but also the sideshot points at the same time. When the
traverse is closed, the closing errors of coordinates are calculated and the corner points can be
adjusted. In addition, the sideshot points from the corner point based on the adjusted each corner
point’s coordinates are calculated.
One point of the traverse data uses the memory size of two or three coordinates data. Therefore,
please confirm the remaining memory. The calculation type is the compass rule.
The traverse function can store the polar coordinates data and the rectangular coordinates data. And
it can send the polar data by DC1 or AUX format and rectangular data by DC1 or CSV format
respectively.
The following assumptions are made:
Sideshot point
Corner point
Known point
Closed traverse
Fixed traverse
Start point
(Coordinates)
End point
(Coordinates)
Direction angle
Back sight point
Open traverse