Adjustment
91
Display Description
ERROR: 330
#Prog. No. #Zone No.
Program. speed > max. gear-controlled speed
ERROR: 331
#Prog. No. #Zone No.
Programmed roller pressure > roller pressure li-
mit
ERROR: 332
#Prog. No. #Zone No.
Speed and differential outside permissible values
ERROR: 340
# Zone No.
Selected temperature too high
ERROR: 341
# Zone No.
Air volume does not match nozzle type
ERROR: 342
# Zone No.
Programmed sealing off not plausible
ERROR: 343
# Zone No.
Programmed output (OUT) not plausible
ERROR: 344
# Program No.
Program not for this machine, nozzle
ERROR: 345
# Zone No.
Section in last program zone smaller than clear-
ance to tape knife (i.e. smaller than length of re-
maining tape)
PROGRAM XX NOT IN MEMORY Program XX does not exist
ERROR: 401 Text fi le cannot be opened
ERROR: 402 Error in read text fi le
ERROR: 501 Error when opening fi le “pikto.hex” or “vorla-
gen.hex”
ERROR: 502 No ACK from control panel
13.11.02 Temperature control error
Error number Description
0 No error
1 Thermoelement 1 disconnection (HW-alarm-bit)
2 Control circuit not reacting
3 Temperature window (alarm) exceeded
4 Thermoelement 2 disconnection (HW-alarm-bit)
5 Thermoelements 1 and 2 exchanged
6 No temperature increase despite of controller full scale (thermoele-
ment possibly not in its holder)