4.2.5.5 RMON History
Configure RMON History table on this page. The RMON History screens in Figure 4-2-45 and Figure 4-2-46 appear.
Figure 4-2-45: RMON History Table Screenshot
The page includes the following fields:
Object
Description
Select Index
Select index from this drop-down list to create the new index or modify the index
Index
Indicates the index of the history entry
Sample Port
Select port from this drop-down list
Bucket Requested
Indicates the maximum data entries associated this History control entry stored
in RMON. The range is from 1 to 50, default value is 50
Interval
Indicates the interval in seconds for sampling the history statistics data. The
range is from 1 to 3600, default value is 1800 seconds.
Owner
Specify an owner for the history
Buttons
: Click to apply changes.
Figure 4-2-46: RMON History Status Screenshot