EasyManuals Logo

Precor TRM700-16 Base User Manual

Precor TRM700-16 Base
186 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #145 background imageLoading...
Page #145 background image
o
If the unit power does not switch "ON" or trips the circuit breaker, see .
Troubleshooting
Tripped Breakers
,
o
If the console does not power up, see
Troubleshooting Console Power.
Verify that the console is operating correctly
Run the Display, and Keypad diagnostic tests (see "Hardware Validation Service Mode
(51765761)" on page21). Resolve any failures.
Note:Keep in mind that if a key on the keypad does not function, the lower control
module will not receive a user initiated request for action. For failed keys problems,
the cause for the failure would not be in the lower PCA or the unit base and no error
codes will be logged.
Review the Error Log or CPA
1
Event Log for any active error codes
Always review the Error Log or CPA Event Log when troubleshooting an issue. The error logs
will contain any triggered error code events and related information. You can then refer to
Error Code Troubleshooting Guide to help resolve the issue. Also, when calling Precor cus-
tomer service for assistance, refer to the Error Log or CPA Event Log for additional inform-
ation to help the representative resolve the issue.
Refer to the Error Code Troubleshooting Guide for error code descriptions and repair infro-
mation.
IMPORTANT: Error Code description and Troubleshooting information is contained in
the
Error Code Troubleshooting Guide
, see Error Code Guide.pdf.
Note:Not all failures trigger an error event code. Many issues are purely mechanical
in nature and therefore cannot trigger an error event code.
Verify (reproduce) the issue.
Operate the unit in normal user mode to verify if the reported failure can be reproduced. Is this
a repeatable or intermittent type failure. Make note of any additional observations (noises,
vibrations, etc.) that occur at the time of the failure which may help resolve the issue.
Note: It is important to keep in mind that some issues are weight (load) related. You
may need to increase the exerciser weight to reproduce the failure.
Perform hardware validation diagnostic tests
Access the Hardware Validation Diagnostic Tests service mode and run any related tests that
might help isolate the cause of the issue, see "Hardware Validation Service Mode
(51765761)" on page21. These tests will help identify good and failed components. Resolve
any resulting failures.
Verify Club settings
1
Control Processing Assembly
Experience Series 700 Line Treadmills
138
6Troubleshooting