ASL PCA Replacement
About
This procedure provides instruction to replace the ASL
1
PCA board.
The Power Entry Assembly located in the front of the treadmill under the frame weldment
cross member contains the Power Cord Inlet Assembly, the ON/OFF SW Circuit Breaker, and
the ASLPCA board. The Power Entry Assembly Bracket must be removed to access these
components.
ID Description
Power Entry Assembly Bracket
Power Cord Inlet Assy
ON/OFF SW Circuit Breaker
ASL PCA Board
Wire Diagram
Power Entry Assembly wire diagram.
1
Active Status Light: Service and maintenance status light.