PowerMeasuringModule PMM
35,0(6
71
Revision 13 EN - 02/2023
13.4 PMM with EtherNet/IP™
The PMM is put into operation with EtherNet/IP™ according to the following scheme:
Address assignment (automatically via DHCP or manually)
Installation of the EDS-file
Transfer of the data to the control unit
The EDS-file contains all identification- and communication parameters of the device. After the integration of
the EDS-file (PRIMES data medium path: Tools/EDS Hardware Installation Tool) the PMM can be added as a
new module.
13.4.1 Module configuration
Insert the PMM module by clicking the right button on Ethernet --> New Module. Enter a device name.
Fig. 13.8: Entering device name and IP-address
13.4.2 Setting the IP address
The IP address is set by means of two hexadecimal coding switches inside the device.
1. Remove the base plate of the device (four hexagon socket screws a. f. 2.5 mm).
Coding switches
Fig. 13.9: Rotary switches for setting the IP address