EasyManua.ls Logo

Primes PROFINET - Page 90

Primes PROFINET
98 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
PowerMeasuringModule PMM
35,0(
6
90
Revision 13 EN - 02/2023
Supply data
Power Supply, Limited energy, SELV
DC IN
DC OUT
24VDC
+25% / -20%; 250mA
24V DC
Bypass on DC IN; the current between
DC IN and DC OUT is max. 5 A.
For devices with the device part numbers listed below, the current between DC IN and DC OUT is max. 16 A.
The device part number can be found on the identification plate.
The identification plate shows as an example the PowerMeasuringModule PMM PROFINET
®
.
Power Supply, Limited energy, SELV
DC IN
DC OUT
500030X
500031X
500032X
500033X
500034X
500035X
24VDC
+25% / -20%; 250mA
24VDC
Bypass on DC IN; the current between
DC IN and DC OUT is max. 16A.
X = all letters and revision numbers following the 6-digit number
Communication
Interface (selectively) PROFINET
®
/ PROFINET
®
LWL (Fiber optics)
PROFIBUS
®
Parallel
DeviceNet™
EtherNet/IP™
EtherCAT
®
Dimensions and weight
Dimensions (LxWxH)
closed
open
200 x 100 x 89mm
246 x 100 x 227mm
Weight (approx.) 2.2kg
Environmental conditions
Operating temperature range 15 – 40°C
Storage temperature range 5 – 50°C
Reference temperature 22°C
Relative humidity (non-condensing) 10 – 80%
Pollution degree 3 (industrial environment)
Max. altitude of operation 3000m
Max. nonoperating altitude 12000m