Preserving and lubricating the machine protects it against corro‐
sion and rapid ageing. This is required if the machine:
● Will be shut down for a longer period,
● Is exposed to corrosive atmospheres during storage or trans‐
port.
NOTICE
Damage to the machine caused by freezing water
▶
If there is a risk of freezing, you must drain the machine and the
delivery line fully of residual water.
1. Perform all steps as described previously in the “Temporary de‐
commissioning” section.
2. Shut down the machine only when de-energised.
3. Lubricate the machine.
4. Preserve the machine with a suitable corrosion protection agent.
9.3 Final decommissioning and disposal
The final decommissioning and disposal requires the complete disas‐
sembly of the machine into its individual components. When dispos‐
ing of all machine components, ensure that there is no possibility of
damage to health or the environment.
WARNING
Risk of injury due to skin contact with functional fluids
Hydraulic fluid and other functional fluids can be injurious to health
in case of skin contact.
▶
Always wear your personal protective equipment when handling
toxic, caustic or other functional fluids that can be injurious to
health and observe the manufacturer’s information.
Decommissioning
9 — 3