The compressor may only be operated using the pressure switch.
Item Designation
1 “Pump ON – OFF” double push-button
2 “"Mix – OFF – Mixing and pumping"” selector switch
3 “Water pump” selector switch
3. Turn the “Mixing – OFF – Mixing and pumping” selector switch
(2)
clockwise to “Mixing and pumping”
⇒
Agitator starts and stops with the pump
4. Turn the “Water pump” selector switch
(3)
clockwise to “Automat‐
ic”
5. Switch on the pump using the double push-button
(1)
.
⇒
The agitator and the mixing pump start running.
6.3.2 Start-up water value
The ideal start-up water value for plaster-based material is 800–900
dm³/h. For non-plaster-based material, this value is 500–600 dm³/h.
Operation
6 — 5