Matrix 832 / 832+ / 424
Page 34 RINS428-5
Log and Event Reporting
Yes - This option allows the engineer to limit the event log entry and report to the Central Monitoring Station to
a total of 16 events in a row for any one event.
No - This option allows the engineer to set the event log entry and report to the Central Monitoring Station for
unlimited number of events.
NOTE: Denmark, Norway, Finland & Sweden – Zone events are limited to 3 per arm period.
Telephone Line Fail
Alarm & Fault Indication - When a telephone line fail occurs, an alarm will activate. A fault will also be
generated on the keypad. To operate this option the “Tel Line Monitoring” option must also be enabled. See
Section 8.1.
Fault Indication Only - When a telephone line fail occurs, only a system fault will be generated on the
keypad and no alarms will be activated.
NOTE: It is possible to program a telephone fault delay time. See Section 7.12.9.
Global Tamper Alarm
0V Applied - This option will enable the engineer to set a change of state sense for the global tamper circuitry
to 0v applied. The global tamper will be activated by applying 0V.
0V Removed - This option will enable the engineer to set a change of state sense for the global tamper
circuitry to 0v removed. The global tamper will be activated by removing 0V.
AC Frequency
60Hz - This option allows the engineer to set the AC mains supply frequency to 60Hz.
50Hz - This option allows the engineer to set the AC mains supply frequency to 50Hz (Europe).
Real Time Clock
Quartz - This option will set the clock accuracy to be driven by the integrated quartz chip.
Mains - This option will set the clock accuracy to be driven by the AC mains frequency.
NOTE: We recommend using the AC derived time-base option and leaving the default value in the
correction factor. Only use quartz derived time-base with unstable AC supplies.

Table of Contents

Other manuals for Pyronix Matrix 832

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Pyronix Matrix 832 and is the answer not in the manual?

Pyronix Matrix 832 Specifications

General IconGeneral
BrandPyronix
ModelMatrix 832
CategoryControl Panel
LanguageEnglish

Related product manuals