14 – Command Reference
Set Config Threshold
59183-02 A 14-83
A
Notes The switch will down a port if an alarm condition is not cleared within three
consecutive sampling windows (by default 30 seconds). Reset the port to bring it
back online. An alarm is cleared when the threshold monitoring detects that the
error rate has fallen below the falling trigger.
Examples The following is an example of the Set Config Threshold command:
SANbox #> admin start
SANbox (admin) #> config edit
SANbox (admin-config) #> set config threshold
A list of attributes with formatting and current values will follow.
Enter a new value or simply press the ENTER key to accept the current value.
If you wish to terminate this process before reaching the end of the list
press 'q' or 'Q' and the ENTER key to do so.
ThresholdMonitoringEnabled (True / False) [False ]
CRCErrorsMonitoringEnabled (True / False) [True ]
RisingTrigger (decimal value, 1-1000) [25 ]
FallingTrigger (decimal value, 0-1000) [1 ]
SampleWindow (decimal value, 1-1000 sec) [10 ]
DecodeErrorsMonitoringEnabled (True / False) [True ]
RisingTrigger (decimal value, 1-1000) [25 ]
FallingTrigger (decimal value, 0-1000) [0 ]
SampleWindow (decimal value, 1-1000 sec) [10 ]
ISLMonitoringEnabled (True / False) [True ]
RisingTrigger (decimal value, 1-1000) [2 ]
FallingTrigger (decimal value, 0-1000) [0 ]
SampleWindow (decimal value, 1-1000 sec) [10 ]
LoginMonitoringEnabled (True / False) [True ]
RisingTrigger (decimal value, 1-1000) [5 ]
FallingTrigger (decimal value, 0-1000) [1 ]
SampleWindow (decimal value, 1-1000 sec) [10 ]
LogoutMonitoringEnabled (True / False) [True ]
RisingTrigger (decimal value, 1-1000) [5 ]
FallingTrigger (decimal value, 0-1000) [1 ]
SampleWindow (decimal value, 1-1000 sec) [10 ]
LOSMonitoringEnabled (True / False) [True ]
RisingTrigger (decimal value, 1-1000) [100 ]
FallingTrigger (decimal value, 0-1000) [5 ]
SampleWindow (decimal value, 1-1000 sec) [10 ]
Finished configuring attributes.
This configuration must be saved (see config save command) and activated (see
config activate command) before it can take effect.
To discard this configuration use the config cancel command.

Table of Contents

Other manuals for Qlogic SANbox 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlogic SANbox 5000 Series and is the answer not in the manual?

Qlogic SANbox 5000 Series Specifications

General IconGeneral
BrandQlogic
ModelSANbox 5000 Series
CategorySwitch
LanguageEnglish

Related product manuals