EasyManuals Logo

Qlogic SANbox 5000 Series Interface Guide

Qlogic SANbox 5000 Series
350 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #258 background imageLoading...
Page #258 background image
14 – Command Reference
Show Alarm
14-112 59183-02 A
S
Show Alarm
Displays the alarm log and session output stream display setting.
Authority None
Syntax show alarm
settings
Keywords settings
Displays the status of the parameter that controls the display of alarms in the
session output stream. This parameter is set using the Set Alarm command.
Notes The alarm log is cleared when the switch is reset or power cycled.
Examples The following is an example of the Show Alarm command:
[1][Fri Jan 19 13:50:26.508 UTC 2007][A][1004.000F][Port: 4][Eport Isolating
due to Merge Zone Failure]
[2][Fri Jan 19 13:50:26.513 UTC 2007][A][1004.0030][Topology change, lost
route to switch with domain ID 1]
[3][Sun Jan 21 07:59:28.677 UTC 2007][A][1004.0030][Topology change, lost
route to switch with domain ID 99]
[4][Sun Jan 21 07:59:29.367 UTC 2007][A][1004.0030][Topology change, lost
route to switch with domain ID 101]
The following is an example of the Show Alarm Settings command:
SANbox #> show alarm settings
Current settings for alarm
--------------------------
display ON

Table of Contents

Other manuals for Qlogic SANbox 5000 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Qlogic SANbox 5000 Series and is the answer not in the manual?

Qlogic SANbox 5000 Series Specifications

General IconGeneral
BrandQlogic
ModelSANbox 5000 Series
CategorySwitch
LanguageEnglish

Related product manuals