BIOS ADVANCED SCREEN
3-26
Console Redirection Settings
Figure 3-19. Console Redirection Settings Screen
Version 2.14.1219 - Copyright (C) 2011 American Megatrends, Inc.
Aptio Setup Utility - Copyright (C) 2011 American Megatrends, Inc.
M
ain
Advanced Ch
i
pse
t
Se
rv
e
r Mgm
t
B
oot
Secur
i
ty
Sa
v
e
&
Ex
it
: Select Screen
: Select Item
Enter: Select
+/-: Change Opt.
F1: Genenal Help
F8: Previous Values
F9: Optimized Defaults
F10: Save & Exit
ESC: Exit
COM0
Console Redirection Settings
Terminal Type
Bits per second
Data Bits
Parity
Stop Bits
Flow Control
[ANSI]
[115200]
[8]
[None)
[1]
[None]
Emulation: ANSI: Extended
ASCII char set. VT100:
ASCII char set. VT100+:
Extends VT100 to support
color, function keys, etc.
VT-UTF8: Uses UTF8 encoding
to map Unicode chars onto 1
or more bytes.
Table 3-21: Console Redirection Settings Fields
S
ETUP ITEM OPTIONS HELP TEXT COMMENTS
Terminal Type
[VT100]
[VT100+]
[VT-UTF8]
[ANSI]
Emulation: ANSI:
Extended ASCII char
set. VT100: ASCII char
set. VT100+: Extends
VT100 to support color,
function keys, etc. VT-
UTF8: Uses UTF8
encoding to map
Unicode chars onto 1
or more bytes.
Bits per
second
[9600]
[19200]
[38400]
[57600]
[115200]
Selects serial port
transmission speed.
The speed must be
matched on the other
side. Long or noisy
lines may require lower
speeds.
Data Bits
[7]
[8]
Data Bits.

Table of Contents