CHAPTER TITLE WEB GRAPHICAL USER INTERFACE (GUI) FOR ESMS
4-33
Procedure:
1. Select the LAN Interface from the drop down list.
2. Check Enable to enable the LAN Settings.
3. In IPv4 Configuration, enable Use DHCP to Obtain an IP
address automatically to dynamically configure IPv4
address using DHCP.
4. If the field is disabled, enter the IPv4 Address, Subnet
Mask and Default Gateway in the respective fields.
5. In IPv6 Configuration, if you wish to enable the IPv6 set-
tings, check Enable.
6. If the IPv6 setting is enabled, enable or disable the option
Use DHCP for obtaining the IP address automatically.
7. If the field is disabled, enter the IPv6 Address, Subnet
Prefix length and Default Gateway in the given field.
8. In VLAN Configuration, if you wish to enable the VLAN
settings, check Enable.
9. Enter the VLAN ID in the specified field.
10.Enter the VLAN Priority in the specified field.
11.Click Save to save the entries.
12.Click Reset if you want to reset the modified changes.
PEF
Platform Event Filtering (PEF) provides a mechanism for con-
figuring the BMC to take selected actions on event messages
that it receives or has internally generated. These actions
include operations such as system power-off, system reset, as
well as triggering the generation of an alert. In MegaRAC GUI,
the PEF Management is used to configure the following fea-
tures:
Event Filter
Alert Policy
LAN Destination
To open PEF Management Settings page, click Configurations
> PEF from the main menu. A sample screenshot of PEF Man-
agement Settings Page is shown in the screen shot below
along with an explanation of each of the tabs.
Event Filter Tab
A PEF implementation is recommended to provide at least 16
entries in the event filter table. A subset of these entries should
be pre-configured for common system failure events, such as
over-temperature, power system failure, fan failure events, etc.
Remaining entries can be made available for ‘OEM’ or System
Management Software configured events. Note that individual
entries can be tagged as being reserved for system use - so
Reset To Reset the modified changes.