CHAPTER TITLE QUANTA SMASH
4-10
/SYS/powerSupply
This command provides the specification of the Sensor Type
sensor-specific event.
*The sensor name list depends on the Server Hardware.
Q&A:
Q1: My system supports two power supply slots and only one
power supply unit connected. What is the other power supply
status?
A1: The other power supply status is " AllDeasserted ".
Q2: My system supports two power supply slots and two power
supply units connected. But only one power cord plugged. What
is the other power supply status?
A2: The other power supply status shows "Presence, Predic-
tiveFail, InputLost(AC/DC) ".
Table 4-8: /SYS/powerSupply
P
ROPERTY
N
AME
VALID VALUE ACCESS DESCRIPTION
Sensor name
list of power
supply
Presence*
FailDetected*
PredictiveFail*
InputLost(AC/DC)*
AllDeasserted
(*Note: Only for
certain models.)
R
Presence
indicates the Power
Supply Presence
detected
FailDetected
indicates the Powser
Supply Failure detected
PredictiveFail
indicates the Power
Supply Predictive
Failure, the status
supported or not
depends on project
InputLost(AC/DC)
indicates the Power
Supply input lost, such
as power cord not
inserted
AllDeasserted
indicates the power
supply is not inserted
Redundancy
FullyRedundant
RedundancyLost
R
The property is provided
depend on project.
FullyRedundant
Indicates the power
redundancy is OK.
RedundancyLost
Indicates the power
redundancy is fail. One
PSU is removed or AC
lost.
Table 4-8: /SYS/powerSupply (Continued)