CHAPTER TITLE WEB GRAPHICAL USER INTERFACE (GUI) FOR ESMS
4-20
screenshot of Sensor Readings page is shown in the following
image:
Figure 4-11. Sensor Readings Page
A brief description of the Sensor Readings page fields is given
in the following sections.
Sensor Type
You can select a specific type of sensor from a drop-down
menu. The list of sensors include the Sensor Name, Status, and
Current Reading. The All Sensors option allows to view all the
available sensor details, and select a specific type of sensor.
When a specific type of sensor is selected, on the right hand
side of the screen will be displayed the Thresholds for the sen-
sor.
The total of six thresholds are available as follows:
Lower Non-Recoverable (LNR)
Lower Critical (LC)
Lower Non-Critical (LNC)
Upper Non-Recoverable (UNR)
Upper Critical (UC)
Upper Non-Critical (UNC)
The threshold states can be Lower Non-critical - going low,
Lower Non-critical - going high, Lower Critical - going low,
Lower Critical - going high, Lower Non-recoverable - going low,
Lower Non-recoverable - going high, Upper Non-critical - going
low, Upper Non-critical - going high, Upper Critical - going low,
Upper Critical - going high, Upper Non-recoverable - going low,
Upper Non-recoverable - going high.
Live Widget
The widget window can be turned On and Off for a selected
sensor. Widget provides a dynamic representation of the read-