EasyManua.ls Logo

Quantum Data 881 - Page 967

Quantum Data 881
1144 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
882 Video Test Instrument User Guide (Rev A.35) 589
XDID
EDID data write
Class EDID and DDC control
Description Writes new EDID structure for DVI Analyzer receiver.
Command syntax XDID offset bytes data
offset (hex)
address offset (in bytes)
bytes
number of bytes
(hex)
data
data
(hex)
Example 1 To change the first 3 bytes of the EDID structure (after the header):
XDID 8 3 DE33FF
DIDU
Example 2 To write at offset 256 (start of block 2):
XDID 100 8 1122334455667788
XDID 108 8 8899AABBCCDDEEFF
DIDU
Related commands DIDA, DIDB, DIDE, DIDK, DIDL, TASK?, DIDP, DIDQ, DIDS, DIDU, EDA<port>:GDID,