882 Video Test Instrument User Guide (Rev A.35) 593
XISH:HINC
Image SHift Horizontal INCrement
Class ImageShift
Description Establishes the horizontal shifting increment value. The value must be less than or equal
to the active horizontal resolution of the current video format, which can be queried with
HRES?. If an imageshift editing session is in progress (the ISHB command was issued),
the value will be changed, but not applied to the hardware until the ISHE and ISHU
commands are issued. Otherwise, the command will take effect immediately.
Command syntax XISH:HINC increment
increment
positive integer number
Query syntax XISH:HINC?
Query response Current horizontal shifting increment value.
Example 1
XISH:HINC 4 //Sets the horizontal shifting increment to 4.
Example 2
XISH:HINC? //Queries for current horizontal shifting increment.
4
Related commands ISHA, ISHB, ISHE, ISHG, ISHK, ISHL, ISHN, ISHP, ISHQ?, ISHS, ISHU, XISH:PATH,
XISH:SRCN, XISH:TINC, XISH:TTYP, XISH:VINC