596 Appendix A Command Reference
XISH:TINC
Image SHift Time INCrement
Class Image Shift
Description Establishes the time shift increment value, which is the number of frames to pause before
shfiting the image. If an imageshift editing session is in progress (the ISHB command was
issued), the value will be changed, but not applied to the hardware until the ISHE and
ISHU commands are issued. Otherwise, the command will take effect immediately.
Command syntax XISH:TINC increment
increment
positive integer number 0 – 999
Query syntax XISH:TINC?
Query response Current time shift increment value.
Example 1
XISH:TINC 2 //Sets the time shift increment to 2.
Example 2
XISH:TINC? //Queries for current time shift increment.
2
Related commands ISHA, ISHB, ISHE, ISHG, ISHK, ISHL, ISHN, ISHP, ISHQ?, ISHS, ISHU, XISH:HINC,
XISH:PATH, XISH:SRCN, XISH:TTYP, XISH:VINC