RADWIN5000ConfigurationGuide Release4.9.17 424
Security ManagingtheSector
5. ClickOK.
6. ClickYeswhenask e difyouwanttochangethelinkpassword.
7. ClickOKatthePasswordchangedsuccessmessage.
RADWINManagerCommunityStrings
TheODUcommunicateswiththeRADWINManagerusingtheSNMPv1orSNMPv3protocol.
TheSNMPv1protocoldefinesthreetypesofcommunities:
•ReadOnlyforretrievinginformationfromtheODU
•ReadWritetoconfigureandcontroltheODU
•TrapusedbytheODUtoissuetraps.
TheCommunitystringmustbeenteredatlogon.Youmustknowthepasswordandthe
correctCommunitystringtogainaccesstothesystem.Youmayhavereadonlyprivileges.Itis
notpossibletomanagetheODUifthereadwriteorthereadCommunityvaluesare
forgotten.AnewCommunityvaluemaybeobtainedfromRADWINCustomerServiceforthe
purposeofsettingnewCommunity.Youmustalsohaveavailablethe serialnumberorthe
MACaddressoftheODU.
ThereadwriteCommunitystringsandreadonlyCommunitystringshaveaminimumoffive
alphanumericcharacters.(bru1andbru4097arenotpermitted).Changingthetrap
Communityisoptionalandisdonebyclickingthecheckbox.
EditingSNMPv1CommunityStrings
Whenediting thesestrings,bothreadwriteandreadonlycommunitiesmustbedefined.
Uponloggingonforthefirsttime,usethefollowingasthecurrentCommunity:
ForReadWriteCommunity,usenetman.
ForReadOnlyCommunity,usepublic.
ForTrapCommunity,usepublic
TochangeaCommunitystring:
1. TypethecurrentreadwriteCommunity(defaultisnetman).
2. Choosethecommunitiestobechangedbyclickingthecheckbox.
Alinkpasswordmustcontainatleasteightbutnomorethan16char
actersexcludingSPACE,TAB,andanyof“>#@|*?;.
RestoringFactoryDefaultsreturnstheLinkPasswordtowireless
p2mp.
Inthissection,“ODUmaybeeitheranHBSoranHSU.