System SP1-xxx
D086/D087 3-30 SM Appendix
160 Pressure:Thin:Low Speed *ENG
[0 to 3 / 3 / 1 /step]
161
Pressure:Thick4 *ENG
[0 to 3 / 3 / 1 /step]
Sets the default pressure position of the fusing unit for thick 4 paper.
0: Depression position (no pressure)
1: Position 1 (less pressure)
2: Position 2
3: Position 3 (strongest pressure)
201
Filler Edge Detection Counter ENG [0 to 9,000,000 / - / 1 /step]
Displays the detection time for the edge of the pressure roller actuator.
1152 [Fusing Nip Band Check]
001 Execute -
[0 or 1 / 0 / 1]
Executes the nip band measurement between heating roller and pressure roller.
If the nip band width is not 8 mm, and fusing is not good, replace the pressure
roller or install a new fusing unit.
002
Pre-Idling Time *ENG
[0 to 255 / 240 / 1 sec/step]
Specifies the fusing rotation time before executing SP1109-001.
003
Stop Time * ENG
[5 to 30 / 20 / 1 sec/step]
Specifies the time for measuring the nip.
004
Pressure Position * ENG
[1 to 3 / 3 / 1 ]
Specifies the pressure position for measuring the nip.