Ricoh Aficio MP C3001 - Sensor Board Unit (Sbu); When Reassembling

Ricoh Aficio MP C3001
1989 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Scanner Unit
SM 4-29 D086/D087
Replacement
and
Adjustment
4.5.5 SENSOR BOARD UNIT (SBU)
1. Exposure glass (
p.4-24)
2. Original length sensor bracket (
p.4-25 "Original Length Sensors")
3. SBU cover bracket [A] (
x 9)
4. Sensor board unit [A] (
x 4, Grand screw x 1, x 2, x 2)
When reassembling
Adjust the following SP modes after you replace the sensor board unit:
SP4–008 (Sub Scan Mag): See "Image Adjustment: Scanning".
SP4–010 (Sub Mag Reg.): See "Image Adjustment: Scanning".
SP4–011 (Main Scan Reg): See "Image Adjustment: Scanning".
SP4–688 (DF: Density Adjustment): Use this to adjust the density level if the ID of
outputs made in the DF and Platen mode is different.