System SP1-xxx
D086/D087 3-34 SM Appendix
071 YOpcDevMot:Low *ENG
[–14 to 14 / 0 / 1 step/step]
072 Fusing: High *ENG
[–4 to 4 / 1.9 / 0.01 %/step]
073 Fusing: Mid *ENG
[–4 to 4 / 1.4 / 0.01 %/step]
074 Fusing: Low *ENG
[–4 to 4 / 1.7 / 0.01 %/step]
075 TransferMot:High *ENG
[–4 to 4 / –0.2 / 0.01 %/step]
076 TransferMot:Mid *ENG
077 TransferMot:Low *ENG
078 TonerMot *ENG
[–30 to 30 / 10 / 5 %/step]
079 Fusing Exit Motor: 1200 *ENG
[–4 to 4 / 2.1 / 0.01 %/step]
100
Drum Adjust *ENG
[0 or 1 / 1 / 1]
0: Off, 1: On
Enables or disables the drum amplitude adjustment.
101 MOpcDevMot:High *ENG
[–7 to 7 / 0 / 1 step/step]
102 COpcDevMot:High *ENG
103 YOpcDevMot:High *ENG
104 MOpcDevMot:Mid *ENG
[–7 to 7 / 0 / 1 step/step]
105 COpcDevMot:Mid *ENG
106 YOpcDevMot:Mid *ENG
107 MOpcDevMot:Low *ENG
[–14 to 14 / 0 / 1 step/step]
108 COpcDevMot:Low *ENG
109 YOpcDevMot:Low *ENG